Home/Acoustics & Speakers

Reverberation Time (RT60)

Sabine reverb time per octave band from room size and surface materials.

Room & surfaces

m
m
m
m²

Reverberation time

RT60 mid (500 Hz – 1 kHz)
3s
Volume
384m³
Surface area
352m²
Bass ratio
0.4
RT low / RT mid (1.0–1.3 is warm)
Mean absorption ᾱ (1 kHz)
0.05
Target for club / amplified music: 0.6–1.2 s. Too live by 1.8 s: add absorption (treatment slider) or fill the room with people.

Per octave band

target range0.00.51.01.52.02.53.03.54.00.71251.692502.655003.341k2.262k1.514kbars = Sabine · dashed = Eyring · seconds

Band details

BandAbsorption A (m² Sabine)RT60 SabineRT60 Eyringᾱ
125 Hz88.60.7 s0.6 s0.25
250 Hz36.21.69 s1.6 s0.1
500 Hz22.42.65 s2.57 s0.06
1k Hz173.34 s3.27 s0.05
2k Hz23.72.26 s2.19 s0.07
4k Hz29.81.51 s1.47 s0.08

How it works

RT60 is the time it takes for sound to decay by 60 dB after the source stops. Wallace Sabine found it depends only on the room volume and the total absorption: every square metre of surface multiplied by how absorbent it is at that frequency.

Formulas
Sabine: RT60 = 0.161 × V / (A + 4mV)    A = Σ Sᵢ × αᵢ
Eyring: RT60 = 0.161 × V / (−S × ln(1 − ᾱ) + 4mV)
V = 384 m³, A(1 kHz) = 17 m² → 3.34 s
  • Sabine over-estimates RT in very absorbent rooms (ᾱ > 0.3); Eyring is more accurate there. In live rooms the two agree.
  • Absorption coefficients are frequency dependent: thin materials (carpet, foam) do nothing below 250 Hz, which is why treated rooms often end up boomy. The bass ratio readout flags this.
  • People are excellent absorbers. An empty hall can have twice the RT of a full one. Always evaluate with the audience in place.
  • For amplified music, aim low (0.6–1.2 s) so the PA defines the sound; for acoustic music the hall itself is part of the instrument.